Prioritas Indonetwork
Tahun ke-3
CV. KARUNIA MAKMUR PERSADA
http://indonetwork.co.id/karuniamakmur
````061-8361483,75075168, 75044668, 081361177944, 085296373116, 081376851098`
Tweet
Share
Depan
Info Perusahaan
Katalog Produk (325)
MIA-LA, Laboratory....
MICRO, HIGH SPEED....
AUTOCVAVES 23 liter....
GLASS WOOL
BAHAN PEMBUAT SABUN....
GRAMOXONE
RESIN ANION
ROUNDUP
DRY ICE
EASY TOUCH 3 IN 1
Lihat semuanya
JEKEN ULTRASONIC....
Digital Ultrasonic....
Digital Ultrasonic....
Digital Ultrasonic....
Digital Timer PS-D30A....
Digital Ultrasonic....
E Instruments
E1100 Combustion....
E4400 Portable....
E8500 Industrial....
E5500 Emissions....
E2200 Industrial....
KOEHLER INSTRUMENTS
Koehler Instrument....
Koehler Instrument....
Koehler Instrument....
Koehler Instrument....
Koehler Instrument....
LINGKUNGAN HIDUP
LAB. PETERNAKAN
LABORATORY EQUPMENTS
LINGKUNGAN HIDUP
LAB. TEKNIK SIPIL
HANNA INSTRUMENTS
OHAUS
ELECTRICAL MEASURING....
HACH
CHEMICALS
ALAT LABORATORIUM
HANNA INSTRUMENTS
HACH
LABORATORY EQUPMENTS
ELECTRIC AND EQUIPMENTS
ELECTRICAL MEASURING....
TERNAK DAN KELAUTAN
LAB. PETERNAKAN
PRODUK MRC
PRODUK MRC
Hubungi Kami
Kenalkan Kami
Informasi Kontak
Nama:
Ibu IR. WATY SEMBIRING IR. JAMID SIHOMBING [Direktur/CEO/Manajer Umum]
E-mail:
Kirim Pesan
Situs Web:
www.karuniamakmurpersada.com
Pesan Instan:
288E2C5B
Nomer Telpon:
061-8361483, 75044668, 75075168
Nomer HP:
081376851098, 085296373116, 081361177944
Nomer Faks:
061-8361483
Alamat:
JL. LETJEN JAMIN GINTING NO. 16
MEDAN 20141, Sumatera Utara
Indonesia
Email: karuniamakmur@ yahoo.com
Rata-rata Tinjauan Pemakai
Tidak ada ulasan untuk perusahaan ini
Menulis tinjauan
Tanggal Bergabung:
15 Jul. 2009
Terakhir Diperbarui:
06 May. 2013
Katalog Produk
(Gambar)
KYORITSU 4106
Permintaan Penawaran
Negara Asal
Jepang
Keterangan
KYORITSU 4106
Negara Asal: Jepang
Cara Pembayaran: Transfer Bank ( T/ T)
Kemas & Pengiriman: 1 unit
Keterangan: • High test current up to 80mA yielding resolution of 0.001© on 2© range.
• Advanced Filtering method ( based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
• Automatic and Manual selection of the Test Current Frequency in four bands ( 94/ 105/ 111/ 128Hz) . In Automatic mode, KEW 4106 will select the most suitable Frequency.
• Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference ( noise) , Residual Resistance Rk, etc.
• Warning for excessive noise and high Auxiliary Earth Spikes resistance • Large Graphic Display with backlight for readings in poorly illuminated areas.
• Up to 800 measurement results can be saved in the memory and recalled on the display.
• The stored results can be transferred to a PC using the " KEW Report " software and a USB adaptor ( Model 8212-USB) which are included.
• Robust design with IP54 protection.
Earth resistance
Re
( Rg at
Á measurement) ( Function) 2© 20© 200© 2000© 20k© 200k© ( Range) 0.001© 0.01© 0.1© 1© 10© 100© ( Resolution) 0.03~ 2.099© 0.03~ 20.99© 0.3~ 209.9© 3~ 2099© 0.03~ 20.99k© 3~ 209.9k© ( Measuring range) ± 2% rdg± 0.03©
± 2% rdg± 5dgt ( * 1) ( Accuracy)
Auxiliary earth resistance
Rh, Rs : 8% of Re+ Rh+ Rs ( Accuracy)
Earth resistivity
Á : 2© 20© 200© 2000© 20k© 200k© ( Range) 0.1© • m~ 1© • m
Autoranging ( Resolution) 0.2~ 395.6© • m 0.2~ 3956© • m 20~ 39.56k© • m 0.2~ 395.6k© • m 2.0~ 1999k© • m ( Measuring range) Á = 2× À × a× Rg ( * 2) ( Accuracy)
Series interference voltage
Ust ( A.C only) ( * 3) : 50V ( Range) 0.1V ( Resolution) 0~ 50.9Vrms ( Measuring range) ± 2% rdg± 2dgt ( 50/ 60Hz)
± 3% rdg± 2dgt ( 40~ 500Hz) ( Accuracy)
Frequency
Fst : Autoranging ( Range) 0.1Hz 1Hz ( Resolution) 40Hz~ 500Hz ( Measuring range) ± 1% rdg± 2dgt ( Accuracy)
Measuring method : Earth resistance: Fall-of-potential method ( currents and voltages measured via the Probes)
Measurement method of Earth Resistivity ( Á ) : Wenner 4-pole method
Series interference voltage ( earth voltage) : RMS Rectifier ( between the E-S Terminals)
Memory capacity : 800 data
Communication Interface : Model 8212-USB Optical Adaptor
LCD : Dot-matrix 192× 64 monochrome
Over-range Indication : " OL "
Overload Protection : between E-S( P) and between E-H( C) terminals AC280V / 10 sec.
Withstand voltage : between the electrical circuit and enclosure AC3540V( 50/ 60Hz) / 5 sec.
Applicable standards : IEC 61010-1 CAT.III 300V, CAT.IV 150V Pollution degree 2
IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 ( EMC) , IEC 60529 ( IP54)
Power source : DC12V : sizeAA manganese dry battery ( R6P) × 8
( Auto power off: approx. 5 minutes)
Dimensions : 167( L) × 185( W) × 89( D) mm
Weight : approx. 900g ( including batteries)
Accessories : 7229 ( Precision measurement test leads) ,
7238 ( Simplified measurement test leads) ,
8032 ( Auxiliary earth spikes [ 2 spiks/ set] ) × 2 sets ( 4 spikes in total) ,
8200-04 ( Cord reel [ 4 pcs] ) × 1 set,
8212-USB ( USB adaptor with " KEW Report( Software) " ) ,
9121 ( Shoulder strap) ,
9125 ( Carrying case) ,
R6P× 8, Instruction manual, Calibration certificate
Optional : 8212-RS232C ( RS232C adaptor with " KEW Report( Software) " )
( * 1) Auxiliary earth resistance is 100© with Rk correction
( * 2) Depending on the measured Rg. Interval [ a] between auxiliary earth spikes is 1.0~ 30.0m
( * 3) This instrument is NOT designed to measure line voltages on commercial powers.