Process Analyzer for Oxygen by Paramagnetic Sensor, Model : 412 Series, Brand : Nova
Keterangan
The Nova 412 Series O2 analyzers utilize a magneto-dynamic paramagnetic measuring cell and powerful selenium cobalt magnet assembly with on-board pre-amplification to provide the highest standard of O2 analysis. Accuracy is further augmented by built-in barometric pressure compensation and detector temperature control. For high purity applications ( Model 412HP) , a high resolution digital readout is added.
Specifications
Method of Detection Magneto-dynamic paramagnetic O2 cell
Ranges Available 412 - any range from 0-2.0% to 0-100.0% O2; 412HP - 98.0 to 100.0 or 0 to 100.00 O2
Resolution
412 - 0.1% O2; 412HP - 0.01% O2
Accuracy & Repeatability
± 0.5% of full scale or 0.05% , whichever is greater
Drift ± 0.2% of full scale per month
Response Time ( T-90) 4-5 seconds
Ambient Temperature Range
32 to 122° F ( 0 to 50° C) @ 5-95% RH non-condensing. Lower temperatures ( -5° F, -20° C) with Cold Weather Package. Sample dew point should be at least 9° F ( 5° C) below lowest sample temperature.
Linearity ± 0.5% of full scale or 0.05% , whichever is greater
Size & Weight
Dimensions will vary depending on enclosure style and options required
Power 115 VAC, 60 Hz - 220 VAC, 50 Hz
Output Options 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
Alarms High and/ or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating
Analyzer Type O2 Analyzer
Hazardous Area Rating Options
General Purpose, Non-Hazardous
Applications
For continuous analysis of oxygen ( O2) in process gas streams that contain gases that interfere with other methods of O2 measurement. For high accuracy or high purity applications.
Features
Highest accuracy O2 analyzer, very stable
Fast response ( T90 - 4 to 5 seconds) and bright digital readout
Linear over entire 0-100% range
Microprocessor control for push button calibration
Non-consumable O2 detector, no periodic replacement required
Built in sample pump or pressure regulator, and 4 - 20 mA outputs
To improve accuracy, detector is mounted in temperature controlled heated box and compensated for changes in barometric pressure at the vent
Options
Hi/ Low gas, low flow, and diagnostic alarms available
Isolated analog, RS232, RS485, MODBUS, and Ethernet outputs available
Sample conditioning systems available for removal of moisture, acidic gas, and dust
Cabinet purge system available for use in hazardous areas
One-step ' cal-now' button with touch screen LCD display
Full automatic calibration with touch screen LCD display
Cold weather package for operation to -20° C ( -4° F)
Cabinet coolers can be fitted to most models
High purity version available for 98-100% O2 ( 412HP)
Calibration
Nitrogen for zero
Air or analyzed calibration gas for span