Electro Acoustic Ear / Octave Sound Level Meter OSCAR 6-7 MERK CASTLE ( DISTRIBUTOR)
Keterangan
Electro Acoustic Ear / Octave Sound Level Meter OSCAR 6-7 MERK CASTLE ( DISTRIBUTOR)
OSHA compliance checks have never been faster
or more convenient. The Tremetrics OSCAR 6 and
OSCAR 7 Electro-Acoustic Ears are the reliable
test subject substitutes that help you generate a
daily legal record to document that your
audiometer is “ in calibration” .
OSCAR 7 is a dual-function instrument, providing
both the daily biological test and the OSHA octave
band sound level check for your test environment.
These dependable units accommodate all
standard and Audiocups earphone enclosures and
include self-guiding, color-coded earphone
couplers so that headsets can be properly
positioned every time. And the best news – a
battery is not required.* The OSCAR 6 does
include a 9-Volt battery for use with other
audiometer models.
Automatic compliance built in
Both the OSCAR 6 and OSCAR 7 models
incorporate the patent-pending ID Wizard™ which
provides compliance documentation.* The
electronic ID insures that the daily OSCAR
biological is automatically compared with the
OSCAR baseline test that was performed when
the audiometer was calibrated. This information is
stored in a Daily Biological Log in the Wizard
audiometer where it can be printed on audiograms
or reports.
How can you know that your testing environment
meets OSHA ambient noise level criteria?
During a hearing test, the new OSCAR 7
continuously monitors the sound levels, pausing
the HT Wizard if noise levels exceed the
maximum acceptable standard. You can be
assured of always being in compliance and
having the confirming documentation on your
audiograms.
SPECIFICATIONS
Daily Biological - OSCAR 6 & 7
Test frequencies: 500, 1000, 2000, 3000, 4000, 6000, 8000 Hz
HL accuracy: ± 2.5 dB
Calibration: For use on audiometers, calibrated to ANSI 3.6-1996
or later. Compliance documentation: Patent-pending ID Wizard™
built in.
Octave Sound Level Monitoring - OSCAR 7
Sound level monitoring: Seven octave bands - 125, 250, 500, 1000,
2000, 4000, 8000 Hz
Test levels: 78 dB at 125 Hz, 64 dB at 250 Hz, 40 dB at 500 Hz,
40 dB at 1000 Hz, 47 dB at 2000 Hz, 50 dB at 4000 Hz,
56 dB at 8000 Hz
Filter: ANSI S1.11-1986, Class II
Calibration is adjusted through front panel
U.S. Patent # 5, 811, 681
Physical
OSCAR 6: 4.5 " H x 7.75 " W x 5.4 " D ( 11.4 cm x 19.7 cm x 13.7
cm) ; weight 1.5 lbs. ( 0.7 kg)
OSCAR 7: 4.2 " H x 6.5 " W x 6.8 " D ( 10.7 cm x 16.5 cm x 17.3 cm) ;
weight 1.63 lbs. ( 0.74 kg)
Couplers: Two each, color-coded, containing a ceramic element
with integral preamplifier
Construction: Sturdy metal housings with provision for wall
mounting
Power: No battery necessary, powered by the HT
Wizard audiometer
OSCAR 6 includes 9-Volt battery for use with other
audiometer models. Battery is accessible without tools
Be sure to specify the make and model of the
audiometer that you will be using. The OSCAR 6 is
compatible with most manual, self-recording and
microprocessor audiometers. The OSCAR 7 is available
for use with the Tremetrics HT Wizard audiometer.