Nama: Tn. rofiq Rohman [Pemasaran] E-mail:
Situs Web:
Nomer Telpon: 021-5374790, 5374791, 53158248 Nomer HP: 0812800 96399 Nomer Faks: 021-53158249 Alamat: Ruko Tol Boulevard Blok G 07, Jl. Pahlawan Seribu BSD City
Tangerang 15322, Banten
Indonesia
www.highvolumeairsampler.com www.sondlevelmeter.com www.alatujiair.com www.alatlingkungan.com/ www.sanitarianfieldkit.com www.personaldustsampler.com www.portablefluegasanalysis.com www.gassamplerambient.com www.ministacksampler.com www.soil-teskit.com w
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan
Tanggal Bergabung: 07 Jan. 2010   Terakhir Diperbarui: 29 May. 2013

Katalog Produk

Emisi Gas Analyzer, Alat Ukur Emisi Kendaraan Bermotor, EMS-5002-5, Emisi Gas Analyzer ( Kendaraan Bermotor) ( EMS-5002-5) , ALAT UJI EMISI KENDARAAN BERMOTOR [ GAS 4/ 5 - BENSIN ] , Exhaust Emission Gas Analyser: Alat Uji Emisi Kendaraan Bensin Kemampuan
HargaEmail ke rofiq_imedha@hotmail.com
Cara PembayaranTransfer Bank (T/T)
Kemas & PengirimanUNIT
Negara AsalAmerika Serikat

Keterangan

FUNGSI : UNTUK MONITORING GAS EMISI KENDARAAN YANG KELUAR DARI KNALPOT ( HC, CO, CO2, O2, AND NO)

SPECIFICATION:
• Ranges: HC: 0 - 2000 ppm
CO: 0 - 10%
CO2: 0 - 20%
O2: 0 - 25%
NO: 0 - 5000 ppm ( Nitric Oxide ) *
• Warm up: Less than 10 minutes
• Display resolution: HC: 1 ppm vol.
CO: 0.01% vol.
CO2: 0.1% vol.
O2: 0.01% vol.
NO: 1ppm*
• Digital display: 3” x 5” LCD Displays all 5 gases, & AFR or LAMDA
• Accuracy ( Bar 97 EPA ASM ) HC: 4 ppm HC
CO: 0.06% CO
CO2: 0.3% CO2
O2: 0.1% O2
NO: 25 ppm*
• Drift: Zero and span drift are less than ± 0.6% of full scale for the first hour
and less than ± 0.4% of full scale per hour thereafter.
• System response time: 7 seconds to 90% of final reading
• Ambient conditions: 35F ( 2C) to 120F ( 45C) , rel. humidity 0-98%
• Sample house: 25 feet ( 7.5 m) with QD coupling 150 Degrees Max.
• Sample probe: Stainless steel 1200 Degrees F ( replaceable flex tip )
• Mass: Approx.: 10 LBS. ( 4.5 Kg )