Anggota Prioritas Prioritas IndonetworkTahun ke-2
Other Website : www.highvolumeairsampler.com www.sondlevelmeter.com www.alatujiair.com ww w.alatlingkungan.com/ www.sanitarianfieldkit.com www.personaldustsampler.com www.portablefluegasanalysis.com www.gassamplerambient.com www.ministacksam
Share
Informasi Kontak
Nama: Tn. rofiq Rohman [Pemasaran] E-mail:
Situs Web:
Nomer Telpon: 021-5374790, 5374791, 53158248 Nomer HP: 0812800 96399 Nomer Faks: 021-53158249 Alamat: Ruko Tol Boulevard Blok G 07, Jl. Pahlawan Seribu BSD City
Tangerang 15322, Banten
Indonesia
www.highvolumeairsampler.com www.sondlevelmeter.com www.alatujiair.com www.alatlingkungan.com/ www.sanitarianfieldkit.com www.personaldustsampler.com www.portablefluegasanalysis.com www.gassamplerambient.com www.ministacksampler.com www.soil-teskit.com w
Whether Station
Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan
Tanggal Bergabung: 07 Jan. 2010   Terakhir Diperbarui: 29 May. 2013

Katalog Produk

Weather Station, Alat Ukur Kecepatan Udara, Arah angin, Kelembaban, Tekanan udara, Curah Hujan. Model : AS-2000
HargaEmail ke rofiq_imedha@hotmail.com
Cara PembayaranTransfer Bank (T/T)
Kemas & PengirimanUNIT
Negara AsalAmerika Serikat

Keterangan

FUNGSI : UNTUK MONITORING CUACA : KECEPATAN ANGIN, ARAH ANGIN, TEMPERATUR UDARA, KELEMBABAN, TEKANAN UDARA, DAN CURAH HUJAN.

Specificatioan :
Data Acquisition Module Reporting units: English or Metric, all measurements Operating power: 10-16 Vdc
Environmental Devices Corp • 4 Wilder Drive Bldg # 15 - Plaistow, NH 03865 •
Tel: ( 603) 378-2112 Fax: ( 603) 378-2113 • E-mail: sales@ hazdust.com
Power consumption: 60 mA maximum Serial port: 9-pin d-sub connector, selectable baud rate, flow control Memory: 128KB RAM, nonvolatile ( 45 days at 15 minute intervals with 6 sensors) Expandable to 256KB or 512KB. Operating Temperature Transducers: -40° to 140° F ( -40° to 60° C) Data acquisition module: -40° to 140° F ( -40° to 60° C) Timekeeping Format: MM/ DD and HH: MM Accuracy: ± 30 seconds/ month Barometric Pressure Range: 28.25 to 30.75 inches Hg Measurement span: 2.50 inches Hg ( 85 hpa) Resolution: ± 0.01 inch Hg or ± 0.3 hpa Altitude offset: 0 to + 10, 000 feet, screwdriver adjustable Absolute Accuracy: .05 inches Hg Wind Speed Range: 0 to 125 mph ( 0-57 m/ s) Resolution: > 0.1 mph Accuracy: ± 1 mph Starting threshold: 0.8 mph Time constant: 2 seconds Wind Direction Range: 0-360° Resolution: > 1% Accuracy: + 1° F Starting threshold: 200-WS-02E: 1.2 mph 200-WS-05E: 0.5mph
Relative Humidity Range: 0-100% RH Accuracy: + 3% ( 10-90% ) Wind Direction Range: 0 - 360° Resolution: > 1% Accuracy: + 3% Solar Radiation ( optional) Sensor: Silicon Pyranometer Spectral range: .4 to 1.1 microns Sensitivity: 80 mV / 1000w/ m² approx Accuracy: + 5%